Eclipse RatioMatic RM Series Guía de instalación

Busca en linea o descarga Guía de instalación para Cocinas Eclipse RatioMatic RM Series. Eclipse RatioMatic RM Series Installation guide Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir

Indice de contenidos

Pagina 1 - RatioMatic

RatioMaticBurnersDesign GuideNo.110 12/01 Version 3.10RM Series

Pagina 2 - WARRANTY

Eclipse RatioMatic v3.10 - Design Guide No. 110, 12/0110Step 1 describes how to select burner options to suit anapplication. Use the RatioMatic Pric

Pagina 3 - About this manual

Eclipse RatioMatic v3.10 - Design Guide No. 110, 12/0111Combustor LengthSelect a combustor length. Optional lengths are availableon some models. No

Pagina 4 - HOW TO GET HELP

Eclipse RatioMatic v3.10 - Design Guide No. 110, 12/01cause a fire or an explosion.Air Flow SwitchThe air flow switch provides a signal to the monito

Pagina 5 - Table of Contents

Eclipse RatioMatic v3.10 - Design Guide No. 110, 12/01All RatioMatics are assembled with a right-hand blower motororientation.All standard RatioMatic

Pagina 6 - Introduction

Eclipse RatioMatic v3.10 - Design Guide No. 110, 12/01Combustion.Ignition TransformerFor the ignition system, use a transformer with:• secondary volt

Pagina 7 - INTRODUCTION

Eclipse RatioMatic v3.10 - Design Guide No. 110, 12/01Ignition Gas PipingRatioMatics are capable of ignition with either low fire orbypass start gas.

Pagina 8 - REPLACEMENT PARTS

Eclipse RatioMatic v3.10 - Design Guide No. 110, 12/01The flame monitoring control system consists of two maincomponents:• Flame Sensor• Flame Monito

Pagina 9 - System Design

Eclipse RatioMatic v3.10 - Design Guide No. 110, 12/01Component SelectionEclipse Combustion can help in the design of a main gas shut-off valve train

Pagina 10 - @ normal conditions)

Eclipse RatioMatic v3.10 - Design Guide No. 110, 12/0118AppendixCONVERSIONFACTORSMetric to English.From To Multiply Bycubic meter (m3) cubic foot (ft3

Pagina 11 - Combustor

Eclipse RatioMatic v3.10 - Design Guide No. 110, 12/0119RatioMaticMain Gas ShutoffValve TrainGas CockSolenoid Valve(normally closed)Fuel Orifice Meter

Pagina 12 - • space limitations

Eclipse RatioMatic v3.10 - Design Guide No. 110, 12/01Copyright I998 by Eclipse Combustion, Inc. All rights reservedworldwide. This publication is p

Pagina 13 - Stoichiometric

Eclipse RatioMatic v3.10 - Design Guide No. 110, 12/01Pressure TapsImpulse LineKEY TO SYSTEMSCHEMATICS (CONTINUED)20Symbol Appearance Name Remarks Bul

Pagina 14

Offered By: Power Equipment Company 2011 Williamsburg Road Richmond, Virginia 23231 Phone (804) 236-3800 Fax (

Pagina 15 - Main gas

Eclipse RatioMatic v3.10 - Design Guide No. 110, 12/01About this manualAUDIENCE3This manual has been written for people who are already familiarwith a

Pagina 16

Eclipse RatioMatic v3.10 - Design Guide No. 110, 12/014There are several special symbols in this document. You mustknow their meaning and importance

Pagina 17

Eclipse RatioMatic v3.10 - Design Guide No. 110, 12/01Table of Contents15About this manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Pagina 18 - Appendix

Eclipse RatioMatic v3.10 - Design Guide No. 110, 12/016IntroductionThe RatioMatic Version 3.10 is a nozzle-mix type burnerdesigned for direct air heat

Pagina 19 - SCHEMATICS

Eclipse RatioMatic v3.10 - Design Guide No. 110, 12/017INTRODUCTIONThis section is provided as a guide for the safe operation of theRatioMatic burner

Pagina 20 - SCHEMATICS (CONTINUED)

Eclipse RatioMatic v3.10 - Design Guide No. 110, 12/01Only qualified personnel, with good mechanical aptitude andexperience on combustion equipment,

Pagina 21

Eclipse RatioMatic v3.10 - Design Guide No. 110, 12/019System DesignDESIGNDesign structureThe design process is divided into the following steps:1. Bu

Comentarios a estos manuales

Sin comentarios