Eclipse RatioMatic v3.10 - Design Guide No. 110, 12/01
cause a fire or an explosion.
Air Flow Switch
The air flow switch provides a signal to the monitoring system
when there is not enough air pressure from the blower. If a
switch is selected, it will be factory mounted.
Warning:
Eclipse Combustion supports the NFPA
regulation requiring, as a minimum standard for
main gas shut-off systems, the use of an air
pressure switch in conjunction with other system
components.
Note:
Standard blower options are listed in Price List 110, additional
blower options are available through Eclipse Combustion. Price
and leadtime may vary.
Power Supply Frequency
Select the 50Hz or 60Hz option. The 50Hz blower motors have
IEC frames and are CE marked. The 60Hz motors have NEMA
frames.
Pressure & Flow
RatioMatics include a combustion air blower.
Blower Motor Type
Motor types include various options: voltages, single or three
phase, TEFC or automotive duty enclosures.
Blower Inlet
When selecting an inlet, consider the following:
amount and size of particles in the air.
sound requirements.
space limitations.
cleanliness requirements of the process.
Motor Orientation
Step 1: Burner Option
Selection (continued)
12
Step 2: Blower Option
Selection
Air
Inlet
Filter
Air flow
Switch
Right-han
d
blower
motor