Eclipse RatioMatic RM Series Guía de instalación Pagina 10

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 21
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 9
Eclipse RatioMatic v3.10 - Design Guide No. 110, 12/01
10
Step 1 describes how to select burner options to suit an
application. Use the RatioMatic Price List 110 and Data Sheets,
Series 110 when following this selection process.
Caution:
Consult EFE-825, Eclipse Combustion Engineering Guide, or
contact Eclipse Combustion if you have special conditions or
questions.
Burner Model / Size Selection
Consider the following when selecting the burner size:
Heat Input. Calculate the required heat input to
achieve the required heat balance.
Power Supply Frequency. Burner capacity will vary
with power supply frequency (50Hz or 60Hz power).
Combustion Chamber Pressure. Consider the
effects that large or varying chamber pressures have on
burner performance.
Altitude. The maximum burner capacity is reduced by
approximately 3% each 1000 feet (300 meters) above
sea level.
Combustion Air Supply. Combustion air should be
fresh (20.9% O
2
) and clean (without corrosives).
Combustion Air Temperature. Changes in air supply
temperature can affect the burner capacity. The
combustion air supply temperature should not exceed
250° F.
Fuel Type. Variation in calorific value and density will
affect burner performance.
Fuel Type
Fuel Symbol Gross Heating Value Specific Gravity
Natural gas CH
4
90%+
1000 BTU/ft
3
0.60
1.52
1.95
(40 MJ/m
3
)
(103 MJ/m
3
)
(130 MJ/m
3
)
Propane C
3
H
8
2570 BTU/ft
3
Butane
C
4
H
10
3250 BTU/ft
3
BTU/ft
3
@ standard conditions (MJ/m
3
@ normal conditions)
If using and alternative fuel supply, contact Eclipse Combustion
with an accurate breakdown of the fuel components.
Air Supply
When a standard RatioMatic Version 3.00 burner is ordered, a
combustion air blower is supplied and mounted directly to the
burner body.
Combustor Type
Select a combustor type based on the application. Low
temperature applications use an alloy combustion tube. High
temperature applications use a silicon carbide (SiC) tube or a
refractory block & holder. For vertical down-firing
applications with block and holder, consult factory.
Step 1: Burner Option
Selection
Vista de pagina 9
1 2 ... 5 6 7 8 9 10 11 12 13 14 15 ... 20 21

Comentarios a estos manuales

Sin comentarios