Eclipse AirHeat v2.00, Installation Guide No. 135, 7/99
22
Burner does not achieve
capacity.
• Main gas control valve is not
functioning.
Check actuator and linkage.
• Burner is firing below rated
input.
Check gas pressure differential.
Adjust main gas pressure
regulator as necessary.
• Burner gas holes are plugged.
Inspect gas holes for dirt or lint
as needed.
PROBLEM POSSIBLE CAUSE SOLUTION
• The igniter is not correctly
grounded to the burner.
• Igniter insulator is broken.
Igniter is grounding out.
Not enough gas:
• The gas flow into the burner is
too low.
• Gas valve does not open.
Start-up sequence runs but
burner does not light.
(continued)
Clean the threads on the igniter
and the burner. NOTE: Do not
apply grease to the threads on
the igniter.
Inspect the igniter. Replace if
broken.
Check the start-up settings.
Adjust low fire gas setting if
necessary.
Check the wiring to the
automatic gas shut-off valve.
Check the output from the
flame safeguard.
Open manual gas cock.
No ignition (continued):
• The igniter needs cleaning. Clean the igniter.
• Flamerod grounding out
Replace if necessary.
Inspect and clean sensor.
No flame signal:
• Broken flamerod
• Dirty UV scanner lens
Verify that the flamerod is
installed correctly and is the
correct length.
The low fire flame is weak or
unstable.
• Not enough gas
Check start-up settings and
adjust to increase gas flow.
Check air pressure drop across
the burner and adjust.
• Incorrect air flow setting
The burner does not go to
high fire.
• Not enough gas pressure out of
main gas regulator.
Adjust pressure regulator so
pressure is provided as stated
in Data 135.
Check for clogging of valves and
regulators in gas line. Pressure
regulator may be incorrectly
sized. Replace if necessary.
• Gas pressure drops as input is
increased.
• Main gas control valve is not
functioning.
Check actuator and linkage.